The Importance of Calibrating Fixed Gas Detectors for Safety

3 Min Read | Jul 20, 2023

July 20, 2023 by Melina Mangino

Reading Time: 3 minutes

Fixed gas detectors play a critical role in safeguarding people, places, and the planet against potentially life-threatening gases in environments ranging from high value industrial complexes to laboratories and hazardous confined spaces. However, to ensure their accuracy and reliability, regular calibration is an indispensable practice.

Calibration is usually a two-step procedure – the zero and the span. In the first step, the sensor is zeroed using ambient air after confirming that the target gas is not present or by using a suitable gas from a cylinder. The second step is to expose the instrument to the calibration gas that contains a known concentration of the target gas the sensor is designed to measure. The readings are then adjusted to match these values.

Whether an instrument warns and/or alarms at the proper time depends on its ability to translate the detected concentration of a target gas into an accurate reading.

During calibration, gas detectors perform relative measurements. Rather than independently assessing the quantity of gas present, they measure the concentration of targeted gas within a test gas mixture by comparing real-time sensor response to the sensor’s response to a known concentration of target gas that the instrument is configured to detect and measure. This “known concentration” test gas serves as the instrument’s measurement scale, or reference point.

So, why is this important? Here are a few reasons to consider:

  1. Ensuring Gas Measurement Accuracy and Reliability

    A gas detector that isn’t accurately calibrated can lead to mis-readings, false alarms, and inadequate responses to hazardous situations. Proper calibration fine-tunes the detector’s sensor(s) to maximize speed of response, measurement accuracy, and provide reliable information to personnel required to make informed decisions in critical moments.

  2. Meeting Regulatory Compliance

    Safety regulations and standards are in place for a reason – to protect people, property, and the environment from potential hazards. Many industries are subject to these regulations that dictate the calibration and maintenance of gas detectors.

  3. Mitigating False Alarms and Detection Failures

    A poorly calibrated gas detector can lead to unnecessary evacuations, disruptions, and complacency due to frequent false alarms. Conversely, improper calibration might render a detector insensitive to dangerous gas levels, leaving people and operations vulnerable to potential harm.

  4. Accounting for Changing Environmental Conditions

    Fluctuations in temperature, humidity, and atmospheric pressure can impact the performance of these instruments. Regular calibration adjusts for these variables, ensuring that the sensor maintains its accuracy despite ever-changing conditions.

  5. Combating Sensor Drift and Aging

    Just like any mechanical or electronic component, gas sensors can experience signal drift or degradation over time. When the detector’s current readings deviate from the known reference, proper calibration procedures enable necessary adjustments to the sensor’s output. This adjustment effectively brings the sensor’s response back in line with the original calibration reference, minimizing the impact of sensor drift.

  6. Upholding Record Keeping and Liability

    In the age of accountability, maintaining thorough records of gas detector calibration is a prudent practice. It demonstrates a commitment to safety management and can serve as a valuable resource in case of incidents or accidents. Having well-documented calibration records can potentially mitigate legal liabilities and bolster an organization’s credibility.

  7. Fostering Confidence in Safety Systems

    An accurately calibrated gas detector is not just a piece of equipment; it’s a testament to an organization’s dedication to safety. Regular calibration instills confidence in employees and management that the safety systems are in optimal condition, ready to provide accurate information and timely alerts in case of emergencies.

Conclusion

Routine calibration helps ensure accurate measurements, regulatory compliance, and a reliable defense against hazardous gases. Onsite safety and instrument availability is maximized while mitigating against false alarms at the same time. In a world where safety is paramount, the simple act of calibration speaks volumes about an organization’s commitment to the well-being of its people and the environment.

Recommended for You

Fixed Gas & Flame Detection

UV/IR vs MSIR Flame Technology

September 9, 2024
2 Min Read
Senscient ELDS
Fixed Gas & Flame Detection

Ethylene Gas Leak Detection

August 9, 2024
2 Min Read
Anhydrous Ammonia Tank
Fixed Gas & Flame Detection

Are You Prepared for Ammonia Gas Leaks

January 22, 2024
5 Min Read
Fixed Gas & Flame Detection

In the Know: Navigating the Hazards of Methane Gas Leaks

February 12, 2024
4 Min Read
Share:

Footer

MSA MISSION: That men and women may work in safety and that they, their families, and their communities may live in health throughout the world.

MSASafety.com

  • Construction
  • General Industry
  • Oil & Gas
  • HVAC-R
  • Utilities
  • Fixed Gas & Flame Detection
  • Fire Service
MSA on Facebook   MSA on X   MSA on Instagram   MSA on LinkedIn   MSA on YouTube  

Contact

  • blog@msasafety.com
  • 1-800-672-2222
  • View All Contact Info
  • Subscribe

Other MSA Blogs

  • Fire Service – The Scene
  • FieldServer – The Safety Connection

© 2024 MSA. All rights reserved.

© 2025 MSA . All rights reserved.

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish. Accept Read More
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT